Back-EMF Protection: Why an Isolated Hall Current Sensor IC Is Needed

2026/11/17

1. BLDC Motor Applications

In a BLDC (brushless DC) motor drive system, the MCU typically uses U/V/W three-phase current feedback for PWM control, current regulation, and fault detection. A traditional current-sensing architecture may use shunt-based current sensing, referred to here as the shunt solution. It converts current into a voltage signal and sends it to the MCU’s ADC.


2. Potential Risks to the MCU from Back EMF

When a motor decelerates or is driven by an external force, back EMF can cause energy to flow back to the power supply, raising the bus voltage. In addition, voltage transients generated by high-speed PWM switching may expose the sensing circuit to electrical stress beyond its expected operating conditions. If the current-sensing circuit lacks sufficient voltage withstand capability and protection, these overvoltages may affect the MCU interface through the sensing path, increasing the risk of measurement errors or even component damage.

Reducing the impact of back-EMF-related electrical overstress (EOS) on the MCU’s current-sensing interface is therefore an important consideration in motor-control system design.


Back EMF is the voltage induced in the stator windings by the magnetic flux as the motor rotor spins. Its magnitude depends on the motor speed, magnetic flux, and motor structure, and the resulting transient voltage can reach hundreds of volts. When a motor decelerates after operating at high speed or is driven by an external force, back EMF may change the voltage and current conditions on the U/V/W phase lines. If the sensing circuit’s input range or protection capability is insufficient, the following issues may occur:

1. Distorted sensing signals: Transient interference may couple into the current-sensing signal, causing the MCU’s ADC readings to shift or fluctuate abnormally.

2. OP amp operation beyond its Absolute Maximum Ratings: If the input common-mode range, differential input limits, or protection design is insufficient, transients caused by back EMF may push the OP amp beyond its rated operating conditions.

3. Damage to the MCU interface: Excessive voltage or current may reach the MCU input through the sensing circuit, parasitic coupling, or other electrical paths, exposing the ADC pin to EOS overvoltage and potentially damaging the component.

4. Abnormal control decisions: Incorrect current feedback may cause the MCU to misjudge the motor’s operating state, affecting current control and protection functions.


3. Limitations of the Traditional Shunt Solution

A shunt solution measures the small voltage drop across a shunt resistor, amplifies it through an OP amp, and sends the signal to the MCU. This architecture offers advantages such as low cost and a mature design. However, the electrical relationship between the sensing circuit and the control side depends on how the shunt resistor is configured.


If a sensing node is exposed to a voltage beyond its design range and the OP amp does not have sufficient input protection, the OP amp may exceed its Absolute Maximum Ratings, resulting in inaccurate measurements or component damage. If the abnormal voltage is further conducted to the MCU’s ADC interface, the risk of control errors and interface damage may also increase.


A shunt solution is therefore not inherently unreliable. Its input protection, filtering, grounding, and layout must be designed appropriately for the actual circuit to ensure that electrical stress caused by back EMF does not exceed component ratings.


4. Benefits of the Isolated Hall Current Sensor IC AZHS1525BW

The isolated AZHS1525BW senses conductor current through a magnetic field and uses an integrated electrical isolation barrier to separate the primary conductor from the secondary-side signal circuitry. By integrating current sensing and electrical isolation in a single chip, it eliminates the need for a shunt resistor, isolation amplifier, and isolated power supply, simplifying the BOM and PCB layout.


Compared with a non-isolated shunt solution without an isolation barrier, the contactless current-sensing method of the isolated AZHS1525BW reduces the risk of abnormal motor-side voltages reaching the MCU side through a direct electrical (galvanic) path.


Even when back-EMF-related current changes occur on the motor side, the AZHS1525BW can withstand the effects of such transient currents. Its internal circuitry can also filter high-frequency transients to prevent them from affecting the circuit.


Its key benefits include:

· Electrical isolation: Reduces direct electrical coupling between the motor phase lines and the low-voltage MCU signal side.

· Improved signal reliability: Helps reduce coupling noise caused by switching transients and improves current-feedback quality.

· Bidirectional current monitoring: Measures current in both directions, enabling the MCU to monitor motor current and regenerative current.

· Simplified isolation design: Can reduce the need for some external isolation circuitry and lower design integration complexity.

In Figure 1, the red path should be understood as a “possible abnormal coupling or conduction path.” It does not mean that back EMF will necessarily reach the MCU through that path. An isolated Hall IC can prevent direct electrical conduction, but the protection effectiveness must still be verified against the actual circuit topology, isolation specifications, and test results.


In addition to electrical isolation, the AZHS1525BW offers clear system-integration benefits. Compared with an isolated shunt solution that requires a shunt resistor, isolation amplifier, and isolated power supply, the AZHS1525BW integrates current sensing and electrical isolation in a single chip, reducing the BOM and PCB area significantly. Its primary-conductor resistance is only 1.06 mΩ, resulting in power dissipation of approximately 35 mW at 5 V. This helps reduce heat generation in high-current applications and eases thermal-design requirements. Because it uses magnetic sensing, its output is not directly affected by PWM common-mode voltage swings on the phase lines, allowing it to be used for in-line phase-current measurement without a high common-mode voltage amplifier. It also requires no four-wire measurement connections or precision differential routing, reducing the impact of layout and grounding on measurement quality. In addition, the AZHS1525BW has passed safety certifications including UL 62368-1 (Ed. 3), which can help shorten end-product system certification timelines. See the comparison table below.


Item Non-isolated Shunt Solution AZHS1525BW
Electrical Isolation No Yes (5000 Vrms)
Main Component Count 2–3 1
Shunt + amplifier /
isolation amplifier
+ isolated DC-DC
Conduction Loss Medium Low (1.06 mΩ)
Isolated Power Supply Required Not required
Phase-Line Common-Mode Impact Requires a high-CMRR amplifier Not directly affected
Layout Requirements Requires four-wire measurement routing No four-wire measurement routing required
Safety Certification — UL 62368-1 (Ed. 3)


5. Conclusion

For motor-current-sensing applications with a risk of back EMF, the isolated AZHS1525BW is recommended for consideration to effectively separate the high-voltage motor-side circuitry from the MCU’s low-voltage control side. Compared with a shunt solution, the isolated AZHS1525BW can prevent abnormal voltages from reaching the MCU through a direct electrical path, improving the safety of the current-sensing interface and overall system reliability.


From a product-selection and system-design perspective, isolation should be treated as a primary design consideration in motor applications involving high voltages and electrical stress. By using the isolated AZHS1525BW together with component ratings and input protection designed for actual operating conditions, designers can build a more robust motor-current-sensing architecture and reduce the impact of back-EMF-related electrical risks on the MCU.